Start with a worked example
Loads the standard’s Annex B inputs and calculates the chart factors automatically. Digitized readings can differ from the printed example factors.
Enter calculation inputs, or load a worked example.
Results use approximate automatic chart readings and the selected loading case. Review the calculation basis and source discrepancy below.
Stress and fatigue checks
| Check | Actual MPa | Allowable MPa | Utilisation | Result |
|---|
Utilisation = actual / allowable. A value ≤ 100% meets the calculated stress limit. Total effective-stress allowable = Ftotal × SMYS. Pressure and fatigue allowables use the main factor F.
Temperature cases
| Operating temperature | S₁ MPa | S₂ MPa | S₃ MPa | Seff MPa |
|---|
Both temperatures use the entered maximum operating pressure. Thermal stress uses Es in MPa throughout.
Calculation breakdown
Factors and calculation basis
Charts used in this calculation
Save This Calculation
Scope of this calculation
Uncased welded steel pipe at highway and railway crossings, using clauses 4.7–4.8. Chart interpolation remains within the individual design curves. Cased crossings, directional drilling, utility tunnels and special loads require a separate assessment.
Factors are interpolated automatically from digitized curves and included in the results, saved calculation and report.