Compressibility factors, Z
Z is dimensionless and calculated from the gas composition using AGA8 DETAIL. Operating Z uses the pipe pressure and temperature; reference Z uses the selected standard or normal conditions. Both are used to convert between reference and actual flow.
Enter flow and pipe dimensions to calculate velocity.
All pipe sections
Selected pipe section
Flow conversion & pipe bore
Calculation
Composition used
| Component | Volume / mole % |
|---|
Save This Calculation
Sources & calculation basis
Composition: GIS/V8:2019, Annex B, “Typical Composition of Natural Gas”, page 6, from the supplied corrected document.
Compressibility: NIST AGA8 DETAIL, calculated separately at operating and reference conditions.
Velocity comparison: the user-specified UK gas industry convention is 40 m/s for filtered gas and 20 m/s for unfiltered gas. Equality meets the selected limit. This basis is separate from GIS/V8, which supplies the starting mixture.
This calculation assumes single-phase gas; it does not establish dew point, pressure loss or pipe strength.