Product-pipe pulling load
The maximum sectional load and rig-end load can differ. These are calculated loads for the complete idealised profile, not a time history of the pull or total drilling-rig demand.
Bore profile
Section-by-section loads
Positive gravity contribution resists the pull; negative contribution assists it. Curved friction uses 2μ|N|. All forces shown in kN.
Axial & bending stress screen
Properties & solver details
Save This Calculation
Method, source corrections & limits
Source: supplied HDD Pulling Calc Rev 01.xlsx, principally “Pull Load (2)”. Its introduction attributes the method to the PRCI HDD engineering design guide. This implementation follows the equations in the supplied workbook; the referenced PRCI edition has not been independently checked in full.
SI units are used throughout. Net weight w = 9.81 × (steel + coating + contents mass − displaced mud mass), in N/m. Straight-section load: Tout = Tin + π Dc L τmud + μ |w L cos θ| + w L sin θ. Inclination θ is negative downward and positive upward in the pulling direction.
Curved-section load: Tout = Tin + π Dc L τmud + 2μ|N| + w L sin θmean, where Tavg = (Tin + Tout)/2, j = √(EI/Tavg), U = L/j, X = L/4 − (j/2)tanh(U/2), Y = L²/8 − j²[1 − sech(U/2)], and N = [Tavg h − w cos(θmean)Y]/X. Sagitta h = R[1 − cos(Δθ/2)].
The curve’s average-tension equation is solved with a bracketed numerical solver. The Tavg → 0 limit is evaluated without dividing by zero: N → 48 EI h/L³ − 5wL cos(θmean)/8. Solver residuals and iteration counts are shown. Reversed centre contact is flagged because the workbook’s contact approximation needs further assessment for that case.
Axial stress = maximum end tension / steel area. Elastic bending stress = E D/(2R) for each active curve. Their sum is compared with the optional longitudinal allowable, using unrounded values. This is not a complete PRCI installation stress or collapse assessment.
Corrections: the second curve’s average tension uses both actual end tensions; the workbook’s U138 instead references blank U131. Angles are consistently converted to radians. Arc lengths are derived from radius and tangent angles, eliminating inconsistent independent arc lengths. Circular cells are replaced with a solver that reports convergence.
Example geometry: radius 684 m with 10° and 5° changes gives 119.381 m and 59.690 m arcs. The workbook independently enters 118.775 m and 67.044 m. This calculator uses the consistent radii/angles, giving a 243.255 m total rather than the workbook’s separately entered 250 m.
Scope: a steel pipe in a single vertical down–horizontal–up profile with uniform mud, contents and friction. It excludes horizontal steering, reverse curves, breakover bends outside the bore, reaming/drill-string resistance, pressure-induced stresses and transient sticking. Supply a separate back-tension allowance for surface handling. The source’s unused SMYS and Poisson ratio inputs are not treated as acceptance criteria.